{"id":2482,"date":"2022-06-22T08:57:21","date_gmt":"2022-06-22T01:57:21","guid":{"rendered":"https:\/\/chuongnhan.vn\/?post_type=product&#038;p=2482"},"modified":"2025-08-07T09:36:39","modified_gmt":"2025-08-07T02:36:39","slug":"automatic-glycohemoglobin-amalyzer-ha-8380v","status":"publish","type":"product","link":"https:\/\/chuongnhan.vn\/en\/product\/automatic-glycohemoglobin-amalyzer-ha-8380v\/","title":{"rendered":"Automatic Glycohemoglobin Amalyzer HA-8380V"},"content":{"rendered":"<p>&nbsp;<\/p>\n<table border=\"1\" width=\"962\" frame=\"border\">\n<tbody>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\"><strong>SPECIFICATIONS<\/strong><\/td>\n<td style=\"height: 42px;\"><\/td>\n<\/tr>\n<tr style=\"height: 47px;\">\n<td style=\"height: 47px;\">Model<\/td>\n<td style=\"height: 47px;\">ADAMS A<sub>1c<\/sub>\u00a0Lite HA-8380V<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Samples<\/td>\n<td style=\"height: 42px;\">Whole blood or Hemolysates<\/td>\n<\/tr>\n<tr style=\"height: 134px;\">\n<td style=\"height: 134px;\">Measured items<\/td>\n<td style=\"height: 134px;\">HbA<sub>1c<\/sub>\u00a0(stable HbA1c ) v\u00e0 HbF<\/p>\n<p>(HbS and HbC can be detected in the Variant mode)<\/td>\n<\/tr>\n<tr style=\"height: 79px;\">\n<td style=\"height: 79px;\">Measurements range<\/td>\n<td style=\"height: 79px;\">HbA<sub>1c<\/sub>\u00a0: 3 &#8211; 20%, 9 &#8211; 195mmol\/mol<\/p>\n<p>HbF : 0 &#8211; 100%<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Measurement principle<\/td>\n<td style=\"height: 42px;\">HPLC method<\/p>\n<p>(Reserved-phase cation exchange chromatography)<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Detection method<\/td>\n<td style=\"height: 42px;\">Dual-wavelength colorimetry<\/p>\n<p>(Wavelengths measured: 420nm \/ 500nm<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Sampling method<\/td>\n<td style=\"height: 42px;\">Cap-piercing<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Resolution<\/td>\n<td style=\"height: 42px;\">0,1% Ratio, 1mmol\/mol<\/td>\n<\/tr>\n<tr style=\"height: 107px;\">\n<td style=\"height: 107px;\">Throughput<\/td>\n<td style=\"height: 107px;\">Variant mode: 160 seconds per sample<\/p>\n<p>Fast mode: 100 seconds per sample<\/td>\n<\/tr>\n<tr style=\"height: 148px;\">\n<td style=\"height: 148px;\">Sample volume<\/td>\n<td style=\"height: 148px;\">Whole blood: Approx. 4\u03bcl<\/p>\n<p>Anemia: Approx. 8\u03bcl<\/p>\n<p>Hemolysas: Approx. 350\u03bcl<\/td>\n<\/tr>\n<tr style=\"height: 117px;\">\n<td style=\"height: 117px;\">Min. required sample volume<\/td>\n<td style=\"height: 117px;\">Blood collection tube: Minimum 10mm away from the bottom<\/p>\n<p>Sample cup: 400\u03bcl<\/td>\n<\/tr>\n<tr style=\"height: 90px;\">\n<td style=\"height: 90px;\">Sample container<\/td>\n<td style=\"height: 90px;\">Blood collection tube: 12,3 or 15mm diameters x 75\u00a0 to 100mm length<\/p>\n<p>Cup : 500\u03bcl<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Rack<\/td>\n<td style=\"height: 42px;\">Arkray racks &#8211; 5 samples\/rack<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Sample loading capacity<\/td>\n<td style=\"height: 42px;\">A maximum of 10 samples<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Display<\/td>\n<td style=\"height: 42px;\">20 digits x 2 lines LCD<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Built-in printer<\/td>\n<td style=\"height: 42px;\">Thermal printer, 58mm thermal paper<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Data memory<\/td>\n<td style=\"height: 42px;\">300 measurement results (including calibration results)<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">External dimensions<\/td>\n<td style=\"height: 42px;\">330 (W) x 515 (D) x 485 (H) mm<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Weight<\/td>\n<td style=\"height: 42px;\">Approx. 35 kg<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Power supply<\/td>\n<td style=\"height: 42px;\">AC 100 &#8211; 240V\u00b110%, 50\/60Hz<\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"height: 42px;\">Power input<\/td>\n<td style=\"height: 42px;\">300VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>REAGENTS<\/strong><\/p>\n<table style=\"width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\"><em>Reagents<\/em><\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\"><em>Materials provided<\/em><\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\"><em>Intended for use<\/em><\/td>\n<td style=\"width: 22%;\" width=\"22%\"><em>\u00a0Manufacturer<\/em><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Column Unit 80<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">1 unit\/box<\/p>\n<p>(2500 test\/column)<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Measure HbA1c in blood using reserve- phase cation exchange chromatography<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Eluent 80A<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">600ml x 4 Packs<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Elutes area before A0 and stabilizies the column<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Eluent 80B<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">600ml x 2 Packs<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Elutes Variant Hb (HbC and other)<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Eluent 80CV<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">600ml x 2 Packs<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Elutes A0 and Variant Hb (HbS)<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Hemolysis Washing Solution Lite H<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">2000ml \u00a0x 3 bottles<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Use this products to dilute whole blood samples and to wash the tubes in which samples flow<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Calibrator Lite<\/p>\n<p>(Freeze dried)<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">Low: 5ml x 1 bottle<\/p>\n<p>High: 5ml x 1 bottle<\/p>\n<p>Diluent: 15ml x 1 bottle<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Calibrate each time the column is changed<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">extendSURE HbA1c Control<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">Level 1 : 0,25ml x 4<\/p>\n<p>Level 2 : 0,25ml x 4<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Are disigned as quality control materials to monitor the accuracy and precision of laboratory testing procedures for HbA1c quantitation<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Canterbury Scientic New Zealand<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Control Dilution Set 80<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">Reconstituent :<\/p>\n<p>15 ml x 1 bottle<\/p>\n<p>Diluent\u00a0\u00a080:<\/p>\n<p>250 mlx 1 bottle<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">This set dissolves, dilutes commercial available freeze-dried controls and dilutes whole blood sample<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 19%;\" width=\"19%\">Washing Solution for tubes<\/td>\n<td style=\"width: 24.1818%;\" width=\"26%\">250ml x 1 bottle<\/td>\n<td style=\"width: 25.8182%;\" width=\"24%\">Is used for washing out protein and fat from blood that have adhered to instruments and equipments<\/td>\n<td style=\"width: 22%;\" width=\"22%\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Model: ADAMS A1c Lite HA-8380V<\/p>\n<p>Manufacturer: ARKRAY Inc. Nh\u1eadt B\u1ea3n<\/p>\n<p>Quality: ISO 9001 &#8211; ISO13485<\/p>\n<p><strong>The ADAMS A1c Lite HA-8380v is a diabetes testing equipment for small and medium laboratories\/departments.<\/strong><\/p>","protected":false},"featured_media":1952,"template":"","meta":[],"product_cat":[199,125],"product_tag":[],"_links":{"self":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product\/2482"}],"collection":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/media\/1952"}],"wp:attachment":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/media?parent=2482"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product_cat?post=2482"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product_tag?post=2482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}