{"id":2483,"date":"2022-06-22T08:57:46","date_gmt":"2022-06-22T01:57:46","guid":{"rendered":"https:\/\/chuongnhan.vn\/?post_type=product&#038;p=2483"},"modified":"2025-08-07T09:36:56","modified_gmt":"2025-08-07T02:36:56","slug":"automatic-glycohemoglobin-anlyzer-ha-8180v","status":"publish","type":"product","link":"https:\/\/chuongnhan.vn\/en\/product\/automatic-glycohemoglobin-anlyzer-ha-8180v\/","title":{"rendered":"Automatic Glycohemoglobin Anlyzer HA-8180V"},"content":{"rendered":"<p><strong>SPECIFICATIONS<\/strong><\/p>\n<table style=\"width: 98.8343%; height: 1219px;\">\n<tbody>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Samples<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Whole blood or hemolysis sample<\/td>\n<\/tr>\n<tr style=\"height: 129px;\">\n<td style=\"width: 37.3682%; height: 10px;\" width=\"198\">Measurement items<\/td>\n<td style=\"width: 90.4858%; height: 10px;\" width=\"425\">HbA1c (Stable HbA1c), HbF<\/p>\n<p>(HbS and HbC can be detected in Variant mode)<\/td>\n<\/tr>\n<tr style=\"height: 64px;\">\n<td style=\"width: 37.3682%; height: 64px;\" width=\"198\">Reagents<sup>*1<\/sup><\/td>\n<td style=\"width: 90.4858%; height: 64px;\" width=\"425\">ELUENT 80A, ELUENT 80B, ELUENT 80CV and HEMOLYSIS WASHING SOLUTION 80H<\/td>\n<\/tr>\n<tr style=\"height: 36px;\">\n<td style=\"width: 37.3682%; height: 36px;\" width=\"198\">Column<sup>*2<\/sup><\/td>\n<td style=\"width: 90.4858%; height: 36px;\" width=\"425\">COLUMN UNIT 80<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Measurement principle<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Reserved-phase cation exchange chromatography<\/td>\n<\/tr>\n<tr style=\"height: 106px;\">\n<td style=\"width: 37.3682%; height: 70px;\" width=\"198\">Detection method<\/td>\n<td style=\"width: 90.4858%; height: 70px;\" width=\"425\">Dual-wavelengths colorimetry<\/p>\n<p>(wavelengths measure: 420nm\/500nm)<\/td>\n<\/tr>\n<tr style=\"height: 105px;\">\n<td style=\"width: 37.3682%; height: 22px;\" width=\"198\">Measurement range<\/td>\n<td style=\"width: 90.4858%; height: 22px;\" width=\"425\">HbA1c: 3-20%, 9-195mmol\/mol<\/p>\n<p>HbF: 0-100%<\/td>\n<\/tr>\n<tr style=\"height: 129px;\">\n<td style=\"width: 37.3682%; height: 61px;\" width=\"198\">Guaranteed measurement range<\/td>\n<td style=\"width: 90.4858%; height: 61px;\" width=\"425\">HbA1c: 4-16%, 20-151mmol\/mol<\/p>\n<p>HbF: 0.3-5%<\/td>\n<\/tr>\n<tr style=\"height: 129px;\">\n<td style=\"width: 37.3682%; height: 77px;\" width=\"198\">Processing speed<\/td>\n<td style=\"width: 90.4858%; height: 77px;\" width=\"425\">Variant mode: 90 seconds per sample<\/p>\n<p>Fast mode: 48 seconds per sample<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Sample consumption<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Approx.14mL (whole blood)<\/td>\n<\/tr>\n<tr style=\"height: 183px;\">\n<td style=\"width: 37.3682%; height: 109px;\" width=\"198\">Sample container<\/td>\n<td style=\"width: 90.4858%; height: 109px;\" width=\"425\">Blood collection tube<\/p>\n<p>(12.3 to 15mm diameters) x 75 to 100mm length)<\/p>\n<p>Sample cup (500mL)<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Sampling method<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Cap-Piercing<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Rack type<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">ARKRAY racks<\/td>\n<\/tr>\n<tr style=\"height: 161px;\">\n<td style=\"width: 37.3682%; height: 86px;\" width=\"198\">Number of measurement samples<\/td>\n<td style=\"width: 90.4858%; height: 86px;\" width=\"425\">One-way transportation (factory set): Maximum 50 samples<\/p>\n<p>Loop transportation: Maximum 100 samples<\/td>\n<\/tr>\n<tr style=\"height: 36px;\">\n<td style=\"width: 37.3682%; height: 36px;\" width=\"198\">Column temperature<\/td>\n<td style=\"width: 90.4858%; height: 36px;\" width=\"425\">Approx.40<sup>o<\/sup>C<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Display<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Color graphic LCD with backlight<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Memory capacity<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">900 test results (including calibration results)<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Built-in printer<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Thermal printer, 58mm thermal paper<\/td>\n<\/tr>\n<tr style=\"height: 64px;\">\n<td style=\"width: 37.3682%; height: 35px;\" width=\"198\">External output<\/td>\n<td style=\"width: 90.4858%; height: 35px;\" width=\"425\">Serial 1 port (Can be optionally used as an Ethernet port)<\/td>\n<\/tr>\n<tr style=\"height: 90px;\">\n<td style=\"width: 37.3682%; height: 62px;\" width=\"198\">Measurement conditions<\/td>\n<td style=\"width: 90.4858%; height: 62px;\" width=\"425\">Temperature: 10-30<sup>o<\/sup>C<\/p>\n<p>Humidity: 20-80% relative humidity (non-condensing)<\/td>\n<\/tr>\n<tr style=\"height: 161px;\">\n<td style=\"width: 37.3682%; height: 90px;\" width=\"198\">Required sample volume<\/td>\n<td style=\"width: 90.4858%; height: 90px;\" width=\"425\">Blood collection tube: Minimum 10mm away from the bottom<\/p>\n<p>Sample cup: 400mL or more<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Warm-up time<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Maximum 30 min.<\/td>\n<\/tr>\n<tr style=\"height: 129px;\">\n<td style=\"width: 37.3682%; height: 77px;\" width=\"198\">Dimensions<\/td>\n<td style=\"width: 90.4858%; height: 77px;\" width=\"425\">530 (W) x 530 (D) x 530 (H) mm<\/p>\n<p>Not including the hemolysis washing solution bottle)<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Weight<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Analyzer: Approx. 39kg, Sampler: Approx. 4kg<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Power supply<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">AC100V-240V\u00b110% 50\/60Hz<\/td>\n<\/tr>\n<tr style=\"height: 32px;\">\n<td style=\"width: 37.3682%; height: 32px;\" width=\"198\">Power consumption<\/td>\n<td style=\"width: 90.4858%; height: 32px;\" width=\"425\">Max.300VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><em>*1, *2 Reagents and Column are sold seperately from HA-8180V anlyzer<\/em><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>REAGENTS<\/strong><\/p>\n<table style=\"width: 98.9776%; height: 749px;\" width=\"936\">\n<tbody>\n<tr style=\"height: 49px;\">\n<td style=\"text-align: center; width: 21.615%; height: 49px;\" width=\"217\"><em>Reagents<\/em><\/td>\n<td style=\"text-align: center; width: 21.4243%; height: 49px;\" width=\"236\"><em>Materials provided<\/em><\/td>\n<td style=\"text-align: center; width: 26.7657%; height: 49px;\" width=\"274\"><em>Intended for use<\/em><\/td>\n<td style=\"text-align: center; width: 22.794%; height: 49px;\" width=\"208\"><em>\u00a0Manufacturer<\/em><\/td>\n<\/tr>\n<tr style=\"height: 188px;\">\n<td style=\"width: 21.615%; height: 10px;\" width=\"217\">Column Unit 80<\/td>\n<td style=\"width: 21.4243%; height: 10px;\" width=\"236\">1 unit\/box<\/p>\n<p>(2500 test\/column)<\/td>\n<td style=\"width: 26.7657%; height: 10px;\" width=\"274\">Measure HbA1c in blood using reserve- phase cation exchange chromatography<\/td>\n<td style=\"width: 22.794%; height: 10px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 144px;\">\n<td style=\"width: 21.615%; height: 60px;\" width=\"217\">Eluent 80A<\/td>\n<td style=\"width: 21.4243%; height: 60px;\" width=\"236\">600ml x 4 Packs<\/td>\n<td style=\"width: 26.7657%; height: 60px;\" width=\"274\">Elutes area before A0 and stabilizies the column<\/td>\n<td style=\"width: 22.794%; height: 60px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 96px;\">\n<td style=\"width: 21.615%; height: 62px;\" width=\"217\">Eluent 80B<\/td>\n<td style=\"width: 21.4243%; height: 62px;\" width=\"236\">600ml x 2 Packs<\/td>\n<td style=\"width: 26.7657%; height: 62px;\" width=\"274\">Elutes Variant Hb (HbC and other)<\/td>\n<td style=\"width: 22.794%; height: 62px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 96px;\">\n<td style=\"width: 21.615%; height: 52px;\" width=\"217\">Eluent 80CV<\/td>\n<td style=\"width: 21.4243%; height: 52px;\" width=\"236\">600ml x 2 Packs<\/td>\n<td style=\"width: 26.7657%; height: 52px;\" width=\"274\">Elutes A0 and Variant Hb (HbS)<\/td>\n<td style=\"width: 22.794%; height: 52px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 144px;\">\n<td style=\"width: 21.615%; height: 85px;\" width=\"217\">Hemolysis Washing Solution 80H<\/td>\n<td style=\"width: 21.4243%; height: 85px;\" width=\"236\">2000ml \u00a0x 3 bottles<\/td>\n<td style=\"width: 26.7657%; height: 85px;\" width=\"274\">Use this products to dilute whole blood samples and to wash the tubes in which samples flow<\/td>\n<td style=\"width: 22.794%; height: 85px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 172px;\">\n<td style=\"width: 21.615%; height: 83px;\" width=\"217\">Calibrator 80<\/p>\n<p>(Freeze dried)<\/td>\n<td style=\"width: 21.4243%; height: 83px;\" width=\"236\"><span style=\"font-size: 95%;\">Low: 3ml x 3 bottles<\/span><\/p>\n<p><span style=\"font-size: 95%;\">High: 3ml x 3 bottles<\/span><\/p>\n<p><span style=\"font-size: 95%;\">Diluent: 10ml x 3 bottles<\/span><\/td>\n<td style=\"width: 26.7657%; height: 83px;\" width=\"274\">Calibrate each time the column is changed<\/td>\n<td style=\"width: 22.794%; height: 83px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 154px;\">\n<td style=\"width: 21.615%; height: 131px;\" width=\"217\">extendSURE HbA1c Control<\/td>\n<td style=\"width: 21.4243%; height: 131px;\" width=\"236\">Level 1 : 0,25ml x 4<\/p>\n<p>Level 2 : 0,25ml x 4<\/td>\n<td style=\"width: 26.7657%; height: 131px;\" width=\"274\">The controls are disigned as quality control materials to monitor the accuracy and precision of laboratory testing procedures for HbA1c quantitation<\/td>\n<td style=\"width: 22.794%; height: 131px;\" width=\"208\">Canterbury Scientic New Zealand<\/td>\n<\/tr>\n<tr style=\"height: 234px;\">\n<td style=\"width: 21.615%; height: 129px;\" width=\"217\">Control Dilution Set 80<\/td>\n<td style=\"width: 21.4243%; height: 129px;\" width=\"236\">Reconstituent :<\/p>\n<p><span style=\"font-family: inherit; font-size: inherit;\">15 ml x 1 bottle<\/span><\/p>\n<p>Diluent\u00a0<span style=\"font-family: inherit; font-size: inherit; color: #333333;\">\u00a0<\/span><span style=\"font-family: inherit; font-size: inherit;\">80:<\/span><\/p>\n<p>250 mlx 1 bottle<\/td>\n<td style=\"width: 26.7657%; height: 129px;\">This set dissolves, dilutes commercial available freeze-dried controls and dilutes whole blood sample<\/td>\n<td style=\"width: 22.794%; height: 129px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<tr style=\"height: 144px;\">\n<td style=\"width: 21.615%; height: 88px;\" width=\"217\">Washing Solution for tubes<\/td>\n<td style=\"width: 21.4243%; height: 88px;\" width=\"236\">250ml x 1 bottle<\/td>\n<td style=\"width: 26.7657%; height: 88px;\" width=\"274\">Is used for washing out protein and fat from blood that have adhered to instruments and equipments<\/td>\n<td style=\"width: 22.794%; height: 88px;\" width=\"208\">Arkray Factory Inc.-Japan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Model: ADAMS A1c HA-8180V<\/p>\n<p>Manufacturer: ARKRAY Inc \u2013 Japan<\/p>\n<p><span style=\"font-size: 21.6px;\">Quality: ISO13485; ISO 9001<\/span><\/p>\n<p><strong>The ADAMS A1c HA-8180V is a fully automated Glycohemoglobin (HbA1c) analyzer based on HPLC (High Performance Liquid Chromatography).<\/strong><\/p>\n<p>&nbsp;<\/p>","protected":false},"featured_media":1950,"template":"","meta":[],"product_cat":[199,125],"product_tag":[],"_links":{"self":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product\/2483"}],"collection":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/media\/1950"}],"wp:attachment":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/media?parent=2483"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product_cat?post=2483"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product_tag?post=2483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}