{"id":2832,"date":"2023-11-28T12:10:25","date_gmt":"2023-11-28T05:10:25","guid":{"rendered":"https:\/\/chuongnhan.vn\/?post_type=product&#038;p=2832"},"modified":"2023-12-01T11:01:53","modified_gmt":"2023-12-01T04:01:53","slug":"ma-6000-real-time-quantitative-thermal-cycler","status":"publish","type":"product","link":"https:\/\/chuongnhan.vn\/en\/product\/ma-6000-real-time-quantitative-thermal-cycler\/","title":{"rendered":"MA-6000 Real-Time Quantitative Thermal Cycler"},"content":{"rendered":"<table style=\"height: 866px; width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr style=\"height: 22px;\">\n<td style=\"width: 100%; height: 22px;\" colspan=\"2\">\n<h3><strong>PCR Module<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr style=\"height: 50px;\">\n<td style=\"width: 42.6624%; height: 50px;\" width=\"235\">Sample Capacity<\/td>\n<td style=\"width: 57.3376%; height: 50px;\" width=\"311\">96 Wells*200\u00b5l<\/td>\n<\/tr>\n<tr style=\"height: 50px;\">\n<td style=\"width: 42.6624%; height: 50px;\" width=\"235\">Sample Volume<\/td>\n<td style=\"width: 57.3376%; height: 50px;\" width=\"311\">6-120\u00b5l<\/td>\n<\/tr>\n<tr style=\"height: 93px;\">\n<td style=\"width: 42.6624%; height: 93px;\" width=\"235\">\u00a0Apply Consumables<\/td>\n<td style=\"width: 57.3376%; height: 93px;\" width=\"311\">200\u00b5l Single Tube, 200\u00b5l 8-tube Strip, 96 Well Plate (Half Edge \/ No Edge)<\/td>\n<\/tr>\n<tr style=\"height: 50px;\">\n<td style=\"width: 42.6624%; height: 50px;\" colspan=\"2\"><strong>Thermo Cycler<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Temperature Range<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">4-100\u2103<\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 42.6624%; height: 43px;\" width=\"234\">Maximum Heating\/Cooling Rate<\/td>\n<td style=\"width: 57.3376%; height: 43px;\" width=\"309\">\u22653\u2103\/s<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Temperature Accuracy<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">\u00b1 0. 1\u2103<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Temperature Uniformity<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">\u00b10.25\u2103<\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 42.6624%; height: 43px;\" width=\"234\">No. of Temperature Control Modules<\/td>\n<td style=\"width: 57.3376%; height: 43px;\" width=\"309\">6 Independent Modules<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">No. of Gradient Columns<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">12<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Hot Cover<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">Electric Hot Cover<\/td>\n<\/tr>\n<tr style=\"height: 50px;\">\n<td style=\"width: 100%; height: 50px;\" colspan=\"2\"><strong>Fluorescent<\/strong> <strong>Detection<\/strong> <strong>Sys<\/strong><strong>t<\/strong><strong>em<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Excitation Light Source<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">Full Spectrum Halogen Lamp<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Excitation Spectrum<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">380-780nm<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Detector<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">-20\u2103 CCD<\/td>\n<\/tr>\n<tr style=\"height: 86px;\">\n<td style=\"width: 42.6624%; height: 86px;\" width=\"234\"><strong>\u00a0<\/strong><strong>\u00a0<\/strong>Fluorescence \u00a0Dyes\/Probes<\/td>\n<td style=\"width: 57.3376%; height: 86px;\" width=\"309\"><strong>\u00a0<\/strong>FAM \/ SYBR Green I \/ VIC \/ HEX \/ TET \/ Cy3 \/ Cy3.5 \/ JOE \/ Yellow 555 \/ ROX \/ Texas Red \/ Cy5 \/ Cy5.5\u00a0\/ LC Red \/ Tamara<\/td>\n<\/tr>\n<tr style=\"height: 43px;\">\n<td style=\"width: 42.6624%; height: 43px;\" width=\"234\">Excitation and Detection Medium<\/td>\n<td style=\"width: 57.3376%; height: 43px;\" width=\"309\">Two-way 96 Optical Fibres<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\" width=\"234\">Sample Linear Range<\/td>\n<td style=\"width: 57.3376%; height: 21px;\" width=\"309\">100-1010 Copies<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 100%; height: 21px;\" colspan=\"2\"><strong>Operation Conditions\u00a0<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\">Power Supply <strong><br \/>\n<\/strong><\/td>\n<td style=\"width: 57.3376%; height: 21px;\">100-240V<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\">Frequency<\/td>\n<td style=\"width: 57.3376%; height: 21px;\">50-60Hz<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\">Operating System<\/td>\n<td style=\"width: 57.3376%; height: 21px;\">Win7\/8\/10<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\">External Interface<\/td>\n<td style=\"width: 57.3376%; height: 21px;\">USB 3.0<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\">Dimensions (WxHxD)<\/td>\n<td style=\"width: 57.3376%; height: 21px;\">548\u00d7388\u00d7288mm<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 42.6624%; height: 21px;\">Weight<\/td>\n<td style=\"width: 57.3376%; height: 21px;\">23kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Model: MA-6000<\/p>\n<p>Manufacturer: SANSURE BIOTECH INC. &#8211; China<\/p>\n<p>Quality: ISO 13485<\/p>\n<p>This instrument is intended to use with proper reagents together to carry<br \/>\nquantitative\/qualitative detection and melt curve analysis for nucleic acid derived from human body, such as pathogen and human nucleic acid etc.<\/p>","protected":false},"featured_media":2831,"template":"","meta":[],"product_cat":[199,206,208],"product_tag":[],"_links":{"self":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product\/2832"}],"collection":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/media\/2831"}],"wp:attachment":[{"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/media?parent=2832"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product_cat?post=2832"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chuongnhan.vn\/en\/wp-json\/wp\/v2\/product_tag?post=2832"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}